Wiring
• All wiring runs are to be concealed in ceiling and walls whenever possible.
• Any wiring that is exposed must be as well hidden as possible: tight into
corners or hidden by trim. All bends in wiring will be 90 degrees, and exposed
wires must either run parallel or perpendicular to the floor.
• Wires for a Head End shall not be run exposed down any wall. They shall be in
the wall or in a wire management tray or chase.
• Exposed wiring shall be attached to walls and ceiling by staples securely enough
to avoid wire sagging.
• All wiring that runs horizontally above drop tile ceiling shall be supported every
4 to 5 feet to protect the cable from the stress related to its own weight and
resulting sag.
• Cable shall not be tied to ceiling support system, sprinkler pipes or electrical
conduit.
• Wire dress at the head end shall have signal separation spacing observed.
• Wires exiting a wall will have a trim plate.
• Any retrofit installation shall have a new wiring infrastructure (all wiring except
110V mains) pulled.
• All wiring will be run so that it’s kept at a safe distance from possible
interference sources as specified in Appendix C “Cable Pulls”.