Wiring
All wiring runs are to be concealed in ceiling and walls whenever possible.
Any wiring that is exposed must be as well hidden as possible: tight into
corners or hidden by trim. All bends in wiring will be 90 degrees, and exposed
wires must either run parallel or perpendicular to the floor.
Wires for a Head End shall not be run exposed down any wall. They shall be in
the wall or in a wire management tray or chase.
Exposed wiring shall be attached to walls and ceiling by staples securely enough
to avoid wire sagging.
All wiring that runs horizontally above drop tile ceiling shall be supported every
4 to 5 feet to protect the cable from the stress related to its own weight and
resulting sag.
Cable shall not be tied to ceiling support system, sprinkler pipes or electrical
conduit.
Wire dress at the head end shall have signal separation spacing observed.
Wires exiting a wall will have a trim plate.
Any retrofit installation shall have a new wiring infrastructure (all wiring except
110V mains) pulled.
All wiring will be run so that it’s kept at a safe distance from possible
interference sources as specified in Appendix C “Cable Pulls”.
Confidential Page 29 9/8/2006